Specifications

Media Monitored

Dry Gas

Device Type

Amplified

Maximum Flow Rate

1000 cm³/s

Supply Voltage

15 V dc

Pipe Diameter Range

0.246 in

Maximum Pressure

150psi

Material

Plastic

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

+85°C

Series

AWM40000

Country of Origin

China

Product details

Amplified Airflow Sensor AWM40000 Series

The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.
When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.

Features and Benefits

• Manifold mount/o-ring sealed
• Ceramic flow tube (non-outgassing), 0 to 1000 sccm
• High common mode pressure (150 psi ceramic flow tube only)
• Operating temperature up to 125°C
• High stability at null and full scale

Product Application Information

• Damper control for heating, ventilation, and air conditioning systems
• Gas analysers
• Low vacuum control
• Process control
• Medical respirators and ventilators
• Oxygen concentrators
• Leak detection equipment
• Vent hoods
• Anaesthesia control
• Gas metering
• Gas chromatography

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

90.885 OMR

Each (ex VAT)

95.429 OMR

Each (inc. VAT)

Honeywell Amplified Airflow Sensor, 1000 cm³/s, AWM40000 Series

90.885 OMR

Each (ex VAT)

95.429 OMR

Each (inc. VAT)

Honeywell Amplified Airflow Sensor, 1000 cm³/s, AWM40000 Series
Stock information temporarily unavailable.

Technical Document

Specifications

Media Monitored

Dry Gas

Device Type

Amplified

Maximum Flow Rate

1000 cm³/s

Supply Voltage

15 V dc

Pipe Diameter Range

0.246 in

Maximum Pressure

150psi

Material

Plastic

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

+85°C

Series

AWM40000

Country of Origin

China

Product details

Amplified Airflow Sensor AWM40000 Series

The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.
When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.

Features and Benefits

• Manifold mount/o-ring sealed
• Ceramic flow tube (non-outgassing), 0 to 1000 sccm
• High common mode pressure (150 psi ceramic flow tube only)
• Operating temperature up to 125°C
• High stability at null and full scale

Product Application Information

• Damper control for heating, ventilation, and air conditioning systems
• Gas analysers
• Low vacuum control
• Process control
• Medical respirators and ventilators
• Oxygen concentrators
• Leak detection equipment
• Vent hoods
• Anaesthesia control
• Gas metering
• Gas chromatography