Pepperl + Fuchs 3 Channel Zener Barrier, ATEX

RS Stock No.: 280-6614Brand: Pepperl + FuchsManufacturers Part No.: Z954
brand-logo
View all in Zener & Galvanic Barriers

Technical Document

Specifications

Number of Channels

3

Module Type

Zener Barrier

Barrier Type

Zener Barrier

Maximum Voltage

250V

Hazardous Area Certification

ATEX

Safety Current Resistance

27.27Ω

Supply Voltage

250V ac

Maximum Current

383mA

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

+60°C

Safety Current Maximum

383mA

Safety Voltage Maximum

250 V

Operating Temperature Range

-20 → +60°C

Product details

Z954 Triple Channel

The above drawing shows a RTD temperature sensor in a 3-wire design that relay the measured temperature through a 4.5V 12Ω triple channel zener barrier. The entire system is quasi-floating. All three channels have an identical end to end resistance.Typical application - RTD temperature measuring devices

Isolation Barriers

Pepperl+Fuchs shunt zener diode barriers are for use as safety interfaces between intrinsically safe and non-intrinsically safe circuits. They are manufactured from Makrolon® and designed to conduct electrical signals - in either direction - between safe and hazardous areas and to limit the amount of energy which can be transferred from a safe to a hazardous area in the event of fault conditions occurring in the safe area. All systems shown are licensed for [EEx ia] IIC Class 1, Div1, Groups A-G

You may be interested in

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

84.700 OMR

84.700 OMR Each (ex VAT)

88.935 OMR

88.935 OMR Each (inc. VAT)

Pepperl + Fuchs 3 Channel Zener Barrier, ATEX

84.700 OMR

84.700 OMR Each (ex VAT)

88.935 OMR

88.935 OMR Each (inc. VAT)

Pepperl + Fuchs 3 Channel Zener Barrier, ATEX
Stock information temporarily unavailable.
You may be interested in

Technical Document

Specifications

Number of Channels

3

Module Type

Zener Barrier

Barrier Type

Zener Barrier

Maximum Voltage

250V

Hazardous Area Certification

ATEX

Safety Current Resistance

27.27Ω

Supply Voltage

250V ac

Maximum Current

383mA

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

+60°C

Safety Current Maximum

383mA

Safety Voltage Maximum

250 V

Operating Temperature Range

-20 → +60°C

Product details

Z954 Triple Channel

The above drawing shows a RTD temperature sensor in a 3-wire design that relay the measured temperature through a 4.5V 12Ω triple channel zener barrier. The entire system is quasi-floating. All three channels have an identical end to end resistance.Typical application - RTD temperature measuring devices

Isolation Barriers

Pepperl+Fuchs shunt zener diode barriers are for use as safety interfaces between intrinsically safe and non-intrinsically safe circuits. They are manufactured from Makrolon® and designed to conduct electrical signals - in either direction - between safe and hazardous areas and to limit the amount of energy which can be transferred from a safe to a hazardous area in the event of fault conditions occurring in the safe area. All systems shown are licensed for [EEx ia] IIC Class 1, Div1, Groups A-G