Technical Document
Specifications
Brand
ABBCoil Voltage
240 V ac
Number of Poles
3
Contact Voltage Rating
690 V ac
Contact Current Rating
20 A
Range
B7
Power Rating
5.5 kW
Series
VB7
Normal State Configuration
3NO
Number Of Auxiliary Contacts
1
Auxiliary Contact Configuration
1NC
Terminal Type
Screw
Length
57.5mm
Width
96.5mm
Depth
46.5mm
Maximum Operating Temperature
+55°C
Minimum Operating Temperature
-25°C
Pole and Throw Configuration
3P
Mounting Style
Rail Mount
Country of Origin
Germany
Product details
VB6/VB7 - Compact Rreversing Contactors
The mechanical lock between the two contactors prevents one of the contactors from switching on, as long as the other is still switched on and vice versa.
Switching over reversing contactors too quickly poses the risk of a phase short circuit.
This is the case if the arc of the contactor switching off has not yet extinguished and the contacts of the contactor switching on are already closed.
To avoid this risk, the two contactor coils must be switched to idle for a minimum of 50 ms during the switchover process and electrically locked against each other.
Stock information temporarily unavailable.
Please check again later.
38.270 OMR
Each (ex VAT)
40.184 OMR
Each (inc. VAT)
1
38.270 OMR
Each (ex VAT)
40.184 OMR
Each (inc. VAT)
1
Buy in bulk
quantity | Unit price |
---|---|
1 - 4 | 38.270 OMR |
5 - 9 | 36.855 OMR |
10 - 24 | 35.510 OMR |
25 - 49 | 34.110 OMR |
50+ | 32.655 OMR |
Technical Document
Specifications
Brand
ABBCoil Voltage
240 V ac
Number of Poles
3
Contact Voltage Rating
690 V ac
Contact Current Rating
20 A
Range
B7
Power Rating
5.5 kW
Series
VB7
Normal State Configuration
3NO
Number Of Auxiliary Contacts
1
Auxiliary Contact Configuration
1NC
Terminal Type
Screw
Length
57.5mm
Width
96.5mm
Depth
46.5mm
Maximum Operating Temperature
+55°C
Minimum Operating Temperature
-25°C
Pole and Throw Configuration
3P
Mounting Style
Rail Mount
Country of Origin
Germany
Product details
VB6/VB7 - Compact Rreversing Contactors
The mechanical lock between the two contactors prevents one of the contactors from switching on, as long as the other is still switched on and vice versa.
Switching over reversing contactors too quickly poses the risk of a phase short circuit.
This is the case if the arc of the contactor switching off has not yet extinguished and the contacts of the contactor switching on are already closed.
To avoid this risk, the two contactor coils must be switched to idle for a minimum of 50 ms during the switchover process and electrically locked against each other.