Technical Document
Specifications
Brand
Chauvin ArnouxMultimeter Type
Handheld
Model Number p
CA 5011
Display Type
Analogue
Functions Measured
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance
Absolute Maximum Resistance Measurement
40 MΩ
True RMS
No
Maximum Frequency
10kHz
Safety Category
CAT III 1000V
Safety Category Level
CAT III
Weight
500g
Height
56mm
Minimum Operating Temperature
-10°C
Best Resistance Measurement Accuracy
±2.5 % (analogue)<BR/>1% L ± 2 pt (digital)
Maximum Operating Temperature
+55°C
Battery Type
9V
Safety Category Voltage
1000V
Width
105mm
Best AC Current Accuracy
±2.5 % (analogue)<BR/>2% L ± 5 pt (digital)
Length
160mm
Best AC Voltage Accuracy
±2.5 % (analogue)<BR/>2% L ± 5 pt (digital)
Dimensions
160 x 105 x 56mm
Best DC Voltage Accuracy
±2.5 % (analogue)<BR/>1% L ± 2 pt (digital)
Best DC Current Accuracy
±2.5 % (analogue)<BR/>1,5% L ± 2 pt (digital)
Country of Origin
France
Product details
C.A 5011 Digital / Analogue Multimeter
The C.A 5011 multimeter gives the true RMS value (TRMS) whether the signal is sinusoidal or distorted. It features automatic AC / DC signal recognition.
Two additional readings: - digital for accuracy, backlit - analogue to assess measurement trends.
Shockproof case with a "Multistand" multi-purpose fold-away stand for use at worksites as well as in the lab.
Available in calibrated version.
Standards
IEC 61010-1, cat. III / 1000 V or cat. IV / 600 V
P.O.A.
1
P.O.A.
Stock information temporarily unavailable.
1
Stock information temporarily unavailable.
Technical Document
Specifications
Brand
Chauvin ArnouxMultimeter Type
Handheld
Model Number p
CA 5011
Display Type
Analogue
Functions Measured
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance
Absolute Maximum Resistance Measurement
40 MΩ
True RMS
No
Maximum Frequency
10kHz
Safety Category
CAT III 1000V
Safety Category Level
CAT III
Weight
500g
Height
56mm
Minimum Operating Temperature
-10°C
Best Resistance Measurement Accuracy
±2.5 % (analogue)<BR/>1% L ± 2 pt (digital)
Maximum Operating Temperature
+55°C
Battery Type
9V
Safety Category Voltage
1000V
Width
105mm
Best AC Current Accuracy
±2.5 % (analogue)<BR/>2% L ± 5 pt (digital)
Length
160mm
Best AC Voltage Accuracy
±2.5 % (analogue)<BR/>2% L ± 5 pt (digital)
Dimensions
160 x 105 x 56mm
Best DC Voltage Accuracy
±2.5 % (analogue)<BR/>1% L ± 2 pt (digital)
Best DC Current Accuracy
±2.5 % (analogue)<BR/>1,5% L ± 2 pt (digital)
Country of Origin
France
Product details
C.A 5011 Digital / Analogue Multimeter
The C.A 5011 multimeter gives the true RMS value (TRMS) whether the signal is sinusoidal or distorted. It features automatic AC / DC signal recognition.
Two additional readings: - digital for accuracy, backlit - analogue to assess measurement trends.
Shockproof case with a "Multistand" multi-purpose fold-away stand for use at worksites as well as in the lab.
Available in calibrated version.
Standards
IEC 61010-1, cat. III / 1000 V or cat. IV / 600 V