ABB AF116 AF Contactor, 24 V ac/dc Coil, 3-Pole, 160 A, 55 kW, 3NO, 690 V ac

RS Stock No.: 800-7232Brand: ABBManufacturers Part No.: 1SFL427002R1111 AF116-30-11B-11
brand-logo
View all in Contactors

Technical Document

Specifications

Brand

ABB

Coil Voltage

24 V ac/dc

Number of Poles

3

Contact Voltage Rating

690 V ac

Contact Current Rating

160 A

Range

AF116

Series

AF

Power Rating

55 kW

Normal State Configuration

3NO

Number Of Auxiliary Contacts

2

Auxiliary Contact Configuration

1NO + 1NC

Terminal Type

Bars

Length

126mm

Width

90mm

Depth

126mm

Minimum Operating Temperature

-40°C

Pole and Throw Configuration

3P

Maximum Operating Temperature

+70°C

Control Voltage

60 V

Country of Origin

Sweden

Product details

AF Range Contactors, 3 Pole

AF contactors are AC/DC operated
AF09-AF38 contactors include an electronic coil interface accepting a wide control voltage Ucmin - Ucmax. Only four coils cover control voltages 24 → 500 Vac or 20 → 500 Vdc
AF..Z contactors equipped with a Z coil type allow direct control by 24 Vdc, 500 mA PLC output and obtain a reduced holding coil consumption
AF.Z contactors withstand short dips and voltage interruptions (SEMI F47-0706 compliance)
AF40-AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC, these contactors are of the block type design with 3 main poles.
AF116-AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC
AF190-AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC, these contactors are of the block type design with 3 main poles.
AF contactors have built in surge protection and does not require any additional surge suppressors

Standards

IEC 60947-1 / 60947-4-7 and EN 60947-1 / 60947-4-1

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

286.045 OMR

Each (ex VAT)

300.347 OMR

Each (inc. VAT)

ABB AF116 AF Contactor, 24 V ac/dc Coil, 3-Pole, 160 A, 55 kW, 3NO, 690 V ac

286.045 OMR

Each (ex VAT)

300.347 OMR

Each (inc. VAT)

ABB AF116 AF Contactor, 24 V ac/dc Coil, 3-Pole, 160 A, 55 kW, 3NO, 690 V ac
Stock information temporarily unavailable.

Buy in bulk

quantityUnit price
1 - 4286.045 OMR
5 - 9271.745 OMR
10 - 24261.450 OMR
25 - 49250.985 OMR
50+240.080 OMR

Technical Document

Specifications

Brand

ABB

Coil Voltage

24 V ac/dc

Number of Poles

3

Contact Voltage Rating

690 V ac

Contact Current Rating

160 A

Range

AF116

Series

AF

Power Rating

55 kW

Normal State Configuration

3NO

Number Of Auxiliary Contacts

2

Auxiliary Contact Configuration

1NO + 1NC

Terminal Type

Bars

Length

126mm

Width

90mm

Depth

126mm

Minimum Operating Temperature

-40°C

Pole and Throw Configuration

3P

Maximum Operating Temperature

+70°C

Control Voltage

60 V

Country of Origin

Sweden

Product details

AF Range Contactors, 3 Pole

AF contactors are AC/DC operated
AF09-AF38 contactors include an electronic coil interface accepting a wide control voltage Ucmin - Ucmax. Only four coils cover control voltages 24 → 500 Vac or 20 → 500 Vdc
AF..Z contactors equipped with a Z coil type allow direct control by 24 Vdc, 500 mA PLC output and obtain a reduced holding coil consumption
AF.Z contactors withstand short dips and voltage interruptions (SEMI F47-0706 compliance)
AF40-AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC, these contactors are of the block type design with 3 main poles.
AF116-AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC, AF146 up to 1000 V AC
AF190-AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC, these contactors are of the block type design with 3 main poles.
AF contactors have built in surge protection and does not require any additional surge suppressors

Standards

IEC 60947-1 / 60947-4-7 and EN 60947-1 / 60947-4-1