Technical Document
Specifications
Brand
ABBProduct Type
Safety Module
Series
GATE-D2
Sub Type
Gateway
Mount Type
DIN Rail
For Use With
DeviceNet
Supply Voltage
24 V
Normal State Configuration
NO/2 NC
Number of Inputs
5
Number of Outputs
5
Terminal Type
Spring Clamp
Power Rating
3kW
Hazardous Area Certification
No
Standards/Approvals
No
Product details
Pluto Gateways For Network Connection
The gateways are devices for transfer of data in both directions between the Pluto bus and other fieldbuses. They are made in these versions; GATE-D1 for DeviceNet (733-4849), GATE-E1 for Ethernet using Modbus A second usage for GATE-D1 and GATE-C1 is as a CAN-bridge (repeater) which transfers CAN telegrams between two CAN-buses. This can be useful when long cables are needed. With CANbridge the usage is not limited to any special protocol such as the Pluto CAN bus system, but it can be used for most CAN bus systems.
All gateways from ABB are mounted on a 35 mm DIN rail
24 Vdc operating voltage
The CAN bus and PROFIBUS are galvanic isolated from each other and from the 24 Vdc supply
The bus connectors have terminals for connection of a cable shield
Stock information temporarily unavailable.
262.398 OMR
262.398 OMR Each (ex VAT)
275.518 OMR
275.518 OMR Each (inc. VAT)
1
262.398 OMR
262.398 OMR Each (ex VAT)
275.518 OMR
275.518 OMR Each (inc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 4 | 262.398 OMR |
| 5 - 9 | 249.272 OMR |
| 10 - 24 | 236.170 OMR |
| 25 - 49 | 223.045 OMR |
| 50+ | 212.756 OMR |
Technical Document
Specifications
Brand
ABBProduct Type
Safety Module
Series
GATE-D2
Sub Type
Gateway
Mount Type
DIN Rail
For Use With
DeviceNet
Supply Voltage
24 V
Normal State Configuration
NO/2 NC
Number of Inputs
5
Number of Outputs
5
Terminal Type
Spring Clamp
Power Rating
3kW
Hazardous Area Certification
No
Standards/Approvals
No
Product details
Pluto Gateways For Network Connection
The gateways are devices for transfer of data in both directions between the Pluto bus and other fieldbuses. They are made in these versions; GATE-D1 for DeviceNet (733-4849), GATE-E1 for Ethernet using Modbus A second usage for GATE-D1 and GATE-C1 is as a CAN-bridge (repeater) which transfers CAN telegrams between two CAN-buses. This can be useful when long cables are needed. With CANbridge the usage is not limited to any special protocol such as the Pluto CAN bus system, but it can be used for most CAN bus systems.
All gateways from ABB are mounted on a 35 mm DIN rail
24 Vdc operating voltage
The CAN bus and PROFIBUS are galvanic isolated from each other and from the 24 Vdc supply
The bus connectors have terminals for connection of a cable shield