Block 100 VA DIN Rail Transformer, 230 V ac Primary, 24 V ac Secondary, EN 61558-2-6, IEC 61558-2-6, DIN EN 61558-2-6,

RS Stock No.: 399-2306Brand: BlockManufacturers Part No.: ACT100
brand-logo
View all in DIN Rail Transformers

Technical Document

Specifications

Brand

Block

Product Type

DIN Rail Transformer

Primary Voltage

230 V ac

Secondary Voltage

24 V ac

Mount Type

Panel

Number of Outputs

1

Length

159.0mm

Power

100VA

Width

94.0mm

Depth

63mm

Minimum Operating Frequency

50Hz

Termination Type

Screw

Maximum Operating Frequency

60Hz

Weight

1.85kg

Maximum Operating Temperature

25°C

Standards/Approvals

EN 61558-2-6, IEC 61558-2-6, DIN EN 61558-2-6, VDE 0570 Part 2-6

Country of Origin

Germany

Product details

Isolating Transformers Short Circuit Proof

Short-circuit proof safety isolating transformers
Resin encapsulated transformers
Stable plastic enclosure
Integrated fuse protection and thermal cut-out against overloading and short circuits
Screw-type terminals for the connecting leads on input and output side
Meet the requirements of IEC61 558, EN61 558, VDE0570
Insulation Class B
Construction Class 2
Isolation: 3750 V (Primary to Secondary)

View all in DIN Rail Transformers

Stock information temporarily unavailable.

92.774 OMR

92.774 OMR Each (ex VAT)

97.413 OMR

97.413 OMR Each (inc. VAT)

Block 100 VA DIN Rail Transformer, 230 V ac Primary, 24 V ac Secondary, EN 61558-2-6, IEC 61558-2-6, DIN EN 61558-2-6,

92.774 OMR

92.774 OMR Each (ex VAT)

97.413 OMR

97.413 OMR Each (inc. VAT)

Block 100 VA DIN Rail Transformer, 230 V ac Primary, 24 V ac Secondary, EN 61558-2-6, IEC 61558-2-6, DIN EN 61558-2-6,

Stock information temporarily unavailable.

QuantityUnit price
1 - 2492.774 OMR
25+89.186 OMR

Technical Document

Specifications

Brand

Block

Product Type

DIN Rail Transformer

Primary Voltage

230 V ac

Secondary Voltage

24 V ac

Mount Type

Panel

Number of Outputs

1

Length

159.0mm

Power

100VA

Width

94.0mm

Depth

63mm

Minimum Operating Frequency

50Hz

Termination Type

Screw

Maximum Operating Frequency

60Hz

Weight

1.85kg

Maximum Operating Temperature

25°C

Standards/Approvals

EN 61558-2-6, IEC 61558-2-6, DIN EN 61558-2-6, VDE 0570 Part 2-6

Country of Origin

Germany

Product details

Isolating Transformers Short Circuit Proof

Short-circuit proof safety isolating transformers
Resin encapsulated transformers
Stable plastic enclosure
Integrated fuse protection and thermal cut-out against overloading and short circuits
Screw-type terminals for the connecting leads on input and output side
Meet the requirements of IEC61 558, EN61 558, VDE0570
Insulation Class B
Construction Class 2
Isolation: 3750 V (Primary to Secondary)