Technical Document
Specifications
Brand
FlukeAbsolute Maximum Resistance Measurement
300kΩ
Best Accuracy
±7% + 2 Digits
Measurement Type
Earth Resistance, Interference Frequency, Interference Voltage
Display Type
LCD
Safety Category
CAT II 300 V
Battery Life
6000 Measurements
Battery Type
AA
Power Source
Battery
Weight
1.1kg
Height
133mm
Includes
Battery
Length
250mm
Maximum Operating Temperature
+35°C
Width
187mm
Minimum Operating Temperature
0°C
Model Number p
1625-2
Safety Category Level
CAT II
Safety Category Voltage
300V
Country of Origin
Romania
Product details
Fluke 1625-2 GEO Earth Ground Tester
The Fluke 1625-2 offers data storage and download capabilities via USB port. It's a distinctive earth ground tester that can perform all four types of earth ground measurement.The Earth Ground Tester is able to measure earth ground loop resistances using only clamps. This method does not require the use of earth ground stakes nor the disconnection of ground rods.
3- and 4-pole Fall-of-Potential, earth resistance loop testing
4-pole Soil Resistivity testing
Selective earth ground rod testing using 1 clamp
Stakeless earth ground rod testing using 2 clamps
IP56 rated for outdoor use
Rugged carrying case
USB data storage and transfer
Automatic Frequency Control (AFC), identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value
R* measurement, calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see
Adjustable limits for quicker testing
Supplied with
6 x AA LR6 batteries, 2 x measuring leads 1.5 m, 2 x alligator clips, users manual.
Stock information temporarily unavailable.
Please check again later.
P.O.A.
Calibration type
No Calibration
1
P.O.A.
Calibration type
No Calibration
1
Technical Document
Specifications
Brand
FlukeAbsolute Maximum Resistance Measurement
300kΩ
Best Accuracy
±7% + 2 Digits
Measurement Type
Earth Resistance, Interference Frequency, Interference Voltage
Display Type
LCD
Safety Category
CAT II 300 V
Battery Life
6000 Measurements
Battery Type
AA
Power Source
Battery
Weight
1.1kg
Height
133mm
Includes
Battery
Length
250mm
Maximum Operating Temperature
+35°C
Width
187mm
Minimum Operating Temperature
0°C
Model Number p
1625-2
Safety Category Level
CAT II
Safety Category Voltage
300V
Country of Origin
Romania
Product details
Fluke 1625-2 GEO Earth Ground Tester
The Fluke 1625-2 offers data storage and download capabilities via USB port. It's a distinctive earth ground tester that can perform all four types of earth ground measurement.The Earth Ground Tester is able to measure earth ground loop resistances using only clamps. This method does not require the use of earth ground stakes nor the disconnection of ground rods.
3- and 4-pole Fall-of-Potential, earth resistance loop testing
4-pole Soil Resistivity testing
Selective earth ground rod testing using 1 clamp
Stakeless earth ground rod testing using 2 clamps
IP56 rated for outdoor use
Rugged carrying case
USB data storage and transfer
Automatic Frequency Control (AFC), identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value
R* measurement, calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see
Adjustable limits for quicker testing
Supplied with
6 x AA LR6 batteries, 2 x measuring leads 1.5 m, 2 x alligator clips, users manual.