Honeywell Pressure Sensor Differential

RS Stock No.: 286-692Brand: HoneywellManufacturers Part No.: 26PCCFA6D
brand-logo
View all in Pressure Sensors

Technical Document

Specifications

Pressure Reading Type

Differential

Minimum Pressure Reading

0psi

Maximum Pressure Reading

15psi

Accuracy

±0.25 %

Output Type

Wheatstone Bridge

Media Measured

Nitrogen Gas, Oxygen

Analogue Output

0 → 100 mV

Electrical Connection

4-Pin Connector

Response Time

1 ms

Supply Voltage

2.5 → 16 V dc

Housing Material

Plastic

Maximum Operating Temperature

+85°C

Minimum Operating Temperature

-40°C

Product details

Temperature-compensated pressure sensors, series 26PC

Range of temperature-compensated pressure sensors with voltage output.
Two point calibration.
Differential or relative pressure measurement.
Right pin.
These sensors can be used for measuring positive or negative pressures.
Connection by pins.

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

19.495 OMR

Each (ex VAT)

20.470 OMR

Each (inc VAT)

Honeywell Pressure Sensor Differential

19.495 OMR

Each (ex VAT)

20.470 OMR

Each (inc VAT)

Honeywell Pressure Sensor Differential
Stock information temporarily unavailable.

Buy in bulk

quantityUnit price
1 - 919.495 OMR
10 - 2418.715 OMR
25 - 4917.930 OMR
50 - 9917.155 OMR
100+16.155 OMR

Technical Document

Specifications

Pressure Reading Type

Differential

Minimum Pressure Reading

0psi

Maximum Pressure Reading

15psi

Accuracy

±0.25 %

Output Type

Wheatstone Bridge

Media Measured

Nitrogen Gas, Oxygen

Analogue Output

0 → 100 mV

Electrical Connection

4-Pin Connector

Response Time

1 ms

Supply Voltage

2.5 → 16 V dc

Housing Material

Plastic

Maximum Operating Temperature

+85°C

Minimum Operating Temperature

-40°C

Product details

Temperature-compensated pressure sensors, series 26PC

Range of temperature-compensated pressure sensors with voltage output.
Two point calibration.
Differential or relative pressure measurement.
Right pin.
These sensors can be used for measuring positive or negative pressures.
Connection by pins.