Technical Document
Specifications
Brand
OEPProduct Type
Audio Transformer
Primary DC Resistance
100.4Ω
Secondary DC Resistance
432mΩ
Mount Type
Panel Mount
Termination Type
Solder
Minimum Operating Temperature
130°C
Length
84mm
Depth
68.6mm
Weight
1.8kg
Standards/Approvals
UL94-HB
Series
V78A01F
Width
100 mm
Isolation Voltage
1kVrms
Minimum Operating Frequency
20Hz
Maximum Operating Frequency
40kHz
Construction
Open Frame
Country of Origin
United Kingdom
Product details
OEP V78A01F Audio Output Transformers
V78A01F 25W valve output transformers are constructed with a grain orientated steel core. The core construction reduces distortion and reduces the stray magnetic field. Featuring 24.5% UL taps on the primary output these push-pull transformers have outputs for 4 Ω, 8 Ω and 16 Ω. V78A01F push pull transformers are suitable for use with amplifiers with EL34 valves.
UL94-HB (minimum)
Temperature class B (+130°C) minimum
19 H total primary inductance at 1 kHz
85.7 mH total secondary inductance at 1 kHz
Isolation of primary to secondary is 1 kVrms for 2 seconds
Stock information temporarily unavailable.
96.529 OMR
96.529 OMR Each (ex VAT)
101.355 OMR
101.355 OMR Each (inc. VAT)
1
96.529 OMR
96.529 OMR Each (ex VAT)
101.355 OMR
101.355 OMR Each (inc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 9 | 96.529 OMR |
| 10+ | 96.123 OMR |
Technical Document
Specifications
Brand
OEPProduct Type
Audio Transformer
Primary DC Resistance
100.4Ω
Secondary DC Resistance
432mΩ
Mount Type
Panel Mount
Termination Type
Solder
Minimum Operating Temperature
130°C
Length
84mm
Depth
68.6mm
Weight
1.8kg
Standards/Approvals
UL94-HB
Series
V78A01F
Width
100 mm
Isolation Voltage
1kVrms
Minimum Operating Frequency
20Hz
Maximum Operating Frequency
40kHz
Construction
Open Frame
Country of Origin
United Kingdom
Product details
OEP V78A01F Audio Output Transformers
V78A01F 25W valve output transformers are constructed with a grain orientated steel core. The core construction reduces distortion and reduces the stray magnetic field. Featuring 24.5% UL taps on the primary output these push-pull transformers have outputs for 4 Ω, 8 Ω and 16 Ω. V78A01F push pull transformers are suitable for use with amplifiers with EL34 valves.
UL94-HB (minimum)
Temperature class B (+130°C) minimum
19 H total primary inductance at 1 kHz
85.7 mH total secondary inductance at 1 kHz
Isolation of primary to secondary is 1 kVrms for 2 seconds