RS PRO Coaxial Surge Protection 90 V Maximum Voltage Rating 10kA Maximum Surge Current Coaxial Line Arrester
Technical Document
Specifications
Brand
RS ProSuppressor Type
Coaxial Line Arrester
Maximum Voltage Rating
90 V
Maximum Surge Current
10kA
Minimum Operating Temperature
-30°C
Maximum Operating Temperature
+80°C
Product details
Surge Protectors
These high-energy surge and lighting arrestors have a wide band-width, low VSWR and low insertion loss. Applications include Telemetry, Fixed/Mobile Communication Systems including both transmitters and receivers. The devices have an M5 stud on the base so that they can be chassis mounted, alternatively, they can be mounted on a single-way mounting bracket (288-193) Available in 'N'; BNC and UHF types with female connectors. Maximum transmitted power through the devices is 144W at 50Ω. The protective element is a low capacitance, gas arrestor. Maximum surge current is 10kA and their good frequency specification is achieved by using a silver plated, precision turned body. These devices are factory sealed and no maintenance is required.
Warning
These coax line protectors must be earthed for maximum protection.
In-line Component Cases & Coaxial Line Surge Protectors
Stock information temporarily unavailable.
Please check again later.
47.665 OMR
Each (ex VAT)
50.048 OMR
Each (inc VAT)
1
47.665 OMR
Each (ex VAT)
50.048 OMR
Each (inc VAT)
1
Buy in bulk
quantity | Unit price |
---|---|
1 - 9 | 47.665 OMR |
10 - 24 | 40.120 OMR |
25 - 49 | 36.105 OMR |
50+ | 32.490 OMR |
Technical Document
Specifications
Brand
RS ProSuppressor Type
Coaxial Line Arrester
Maximum Voltage Rating
90 V
Maximum Surge Current
10kA
Minimum Operating Temperature
-30°C
Maximum Operating Temperature
+80°C
Product details
Surge Protectors
These high-energy surge and lighting arrestors have a wide band-width, low VSWR and low insertion loss. Applications include Telemetry, Fixed/Mobile Communication Systems including both transmitters and receivers. The devices have an M5 stud on the base so that they can be chassis mounted, alternatively, they can be mounted on a single-way mounting bracket (288-193) Available in 'N'; BNC and UHF types with female connectors. Maximum transmitted power through the devices is 144W at 50Ω. The protective element is a low capacitance, gas arrestor. Maximum surge current is 10kA and their good frequency specification is achieved by using a silver plated, precision turned body. These devices are factory sealed and no maintenance is required.
Warning
These coax line protectors must be earthed for maximum protection.