RS PRO Variac, 1 Output, 1 Phase 1.92 kVA, 240 V 0 to 240 V, 0 to 270 V

Technical Document
Specifications
Brand
RS ProProduct Type
Variac
Primary Voltage
240 V
Secondary Voltage
0 to 240 V, 0 to 270 V
Mount Type
Surface Mount
Knob Rotation
Clockwise
Power
1.92kVA
Termination Type
Wire Termination
Primary Current
8A
Length
175mm
Depth
130mm
Weight
20kg
Standards/Approvals
No
Maximum Operating Frequency
60Hz
Construction
Open
Number of Phases
1
Product details
Open Style Variable Transformer
Professional range of open style variable transformers available in either single or three phase. The transformers are not designed to provide mains isolation but do operate at mains voltage. The transformers need to be fitted within an enclosure or a protected environment.
A robust range of open style variable transformers for flash mounting within control panels, enclosures or process control equipment
Operating temperature range is 0°C - 105°C.
Single or three phase versions available in a range of current ratings
Continuously variable AC output voltage with overvoltage tap
Heavy duty construction
No wave form distortion
Silver plated commutator
Over-load capacity
Smooth linear output
Negligible maintenance
Trouble free long life
0.7, 2, 3, 5, 8, 10, 15 & 20A versions available
Variable Auto Transformers
Stock information temporarily unavailable.
307.169 OMR
307.169 OMR Each (ex VAT)
322.527 OMR
322.527 OMR Each (inc. VAT)
1
307.169 OMR
307.169 OMR Each (ex VAT)
322.527 OMR
322.527 OMR Each (inc. VAT)
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
RS ProProduct Type
Variac
Primary Voltage
240 V
Secondary Voltage
0 to 240 V, 0 to 270 V
Mount Type
Surface Mount
Knob Rotation
Clockwise
Power
1.92kVA
Termination Type
Wire Termination
Primary Current
8A
Length
175mm
Depth
130mm
Weight
20kg
Standards/Approvals
No
Maximum Operating Frequency
60Hz
Construction
Open
Number of Phases
1
Product details
Open Style Variable Transformer
Professional range of open style variable transformers available in either single or three phase. The transformers are not designed to provide mains isolation but do operate at mains voltage. The transformers need to be fitted within an enclosure or a protected environment.
A robust range of open style variable transformers for flash mounting within control panels, enclosures or process control equipment
Operating temperature range is 0°C - 105°C.
Single or three phase versions available in a range of current ratings
Continuously variable AC output voltage with overvoltage tap
Heavy duty construction
No wave form distortion
Silver plated commutator
Over-load capacity
Smooth linear output
Negligible maintenance
Trouble free long life
0.7, 2, 3, 5, 8, 10, 15 & 20A versions available