Technical Document
Specifications
Brand
United AutomationMounting Type
DIN Rail
Output Isolation
3.5kV
Input Voltage AC
24V ac
Input Voltage DC
24V dc
Pin Count
9
Dimensions
160 x 62 x 62mm
Minimum Operating Temperature
0 °C
Maximum Operating Temperature
+65 °C
Product details
Multi Mode, Phase-Angle & Single/Dual Cycle Burst Firing Circuit, DMFC-36
The DMFC-36 module has been designed to offer Phase-Angle or Burst Fire Control in firing a thyristor assembly or complete thyristor controller for driving resistive loads. In Single-Cycle or Dual-Cycle mode, these modules use the fastest burst rates possible, providing very accurate control and minimising Harmonic distortion & Flicker within the system.
Includes a Transformer
Standard Din Rail Mount
On Board Indication of Power, Burst-Rates & Fault Conditions
Phase-Angle, or Burst Fire Control
Single-Cycle / Dual Cycle Burst Fire modes of control or adjustable Standard Burst Firing
Soft-start (1 to 30 seconds)
Inhibit Input
Wide Range of Control Options: 0-5V, 0-10V, 1-5V, 2-10V, 0-20mA, 4-20mA, Manual Potentiometer
Isolated Pulse transformer outputs
On Board Protection Fuse
163.569 OMR
163.569 OMR Each (ex VAT)
171.747 OMR
171.747 OMR Each (inc. VAT)
1
163.569 OMR
163.569 OMR Each (ex VAT)
171.747 OMR
171.747 OMR Each (inc. VAT)
1
Stock information temporarily unavailable.
Please check again later.
quantity | Unit price |
---|---|
1 - 2 | 163.569 OMR |
3+ | 160.624 OMR |
Technical Document
Specifications
Brand
United AutomationMounting Type
DIN Rail
Output Isolation
3.5kV
Input Voltage AC
24V ac
Input Voltage DC
24V dc
Pin Count
9
Dimensions
160 x 62 x 62mm
Minimum Operating Temperature
0 °C
Maximum Operating Temperature
+65 °C
Product details
Multi Mode, Phase-Angle & Single/Dual Cycle Burst Firing Circuit, DMFC-36
The DMFC-36 module has been designed to offer Phase-Angle or Burst Fire Control in firing a thyristor assembly or complete thyristor controller for driving resistive loads. In Single-Cycle or Dual-Cycle mode, these modules use the fastest burst rates possible, providing very accurate control and minimising Harmonic distortion & Flicker within the system.
Includes a Transformer
Standard Din Rail Mount
On Board Indication of Power, Burst-Rates & Fault Conditions
Phase-Angle, or Burst Fire Control
Single-Cycle / Dual Cycle Burst Fire modes of control or adjustable Standard Burst Firing
Soft-start (1 to 30 seconds)
Inhibit Input
Wide Range of Control Options: 0-5V, 0-10V, 1-5V, 2-10V, 0-20mA, 4-20mA, Manual Potentiometer
Isolated Pulse transformer outputs
On Board Protection Fuse