Technical Document
Specifications
Normal State Configuration
2NO/2NC
Cable Length
2 x 35 → 2 x 100m
IP Rating
IP66
Number of Poles
DPST
Series
XY2CE
Range
Preventa XY2
Length
285mm
Width
106mm
Depth
142mm
Housing Material
Stainless Steel
Hazardous Area Certification
ATEX
Maximum AC Voltage
240V
Maximum Operating Temperature
+70°C
Dimensions
285 x 106 x 142mm
Minimum Operating Temperature
-25°C
Standards Met
CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508
Maximum DC Voltage
250V
Conduit Entry
M20
Country of Origin
Morocco
Product details
Telemecanique XY2CED Emergency Stop Dual Rope Pull Switches
Telemecanique XY2CED emergency stop dual rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. These dual rope pull switches feature double anchor points and can support up to 2 x 100 m with supports and pulleys. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the tripwire breaking.
Features and Benefits
Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m
Stock information temporarily unavailable.
Please check again later.
183.625 OMR
Each (ex VAT)
192.806 OMR
Each (inc VAT)
1
183.625 OMR
Each (ex VAT)
192.806 OMR
Each (inc VAT)
1
Technical Document
Specifications
Normal State Configuration
2NO/2NC
Cable Length
2 x 35 → 2 x 100m
IP Rating
IP66
Number of Poles
DPST
Series
XY2CE
Range
Preventa XY2
Length
285mm
Width
106mm
Depth
142mm
Housing Material
Stainless Steel
Hazardous Area Certification
ATEX
Maximum AC Voltage
240V
Maximum Operating Temperature
+70°C
Dimensions
285 x 106 x 142mm
Minimum Operating Temperature
-25°C
Standards Met
CCC, CSA, CSA C 22-2, EAC, EN/IEC 60947-5-5, UL (NISD), UL 508
Maximum DC Voltage
250V
Conduit Entry
M20
Country of Origin
Morocco
Product details
Telemecanique XY2CED Emergency Stop Dual Rope Pull Switches
Telemecanique XY2CED emergency stop dual rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. These dual rope pull switches feature double anchor points and can support up to 2 x 100 m with supports and pulleys. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the tripwire breaking.
Features and Benefits
Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m